Article

Troubleshooting Corona Generators: Power, Output, Arcing and Heat

Nov 24, 2026Leave a message

A generator that stops treating usually has one of four faults - no power, low output, arcing or overheating. Check them in that order; most "generator failure" calls are a setup problem, not a dead unit.

About HeFeng - HeFeng (Shenzhen Hefengjiada Technology Co., Ltd.) builds corona treatment systems, plasma treaters, static eliminators and contact cleaning equipment. Founded in Taiwan in 1990 with production in Shenzhen since 2000 and a Shanghai factory since 2007, the company holds 20+ patents, ISO 00910Q1198OROS and CE certificates (plasma CE 100914/SHE697; generator CE EC.1282.1E130325.SHE0401), and develops electrodes with AHLBRANDT (Germany) and HILDEBRAND (Switzerland). Send material, web width and line speed; HeFeng replies with a model, the process window and utilities before any build.

Start With the Three Things That Are Not the Generator

Before opening the cabinet, confirm the line is actually asking for treatment: the web is threaded through the station, the speed signal is reaching the generator (0–10 V or 4–20 mA), and the electrode gap is within the set range. A dyne reading taken while the line is ramping, or at the wrong side of the roll, will look like a power fault. Test a clean sample with a dyne pen to ASTM D2578 before concluding the generator is at fault.

No Power

Verify the supply, the main breaker and the emergency-stop circuit first. If the unit has power but no high-voltage output, check that the door interlock and the earth connection are sound - a missing ground is a common cause of a no-start condition and is also a safety issue. HeFeng generators use a grounded frame; a continuity check to <1 Ω is a sensible first test.

Low Output

Low treatment most often comes from process settings, not the power supply. Work through the gap, line speed and power tracking: widen the electrode gap, raise speed, or a power supply that no longer follows the speed signal will all reduce the dyne level at the web. On PE the practical target is 38–40 mN/m and on BOPP 40–42 mN/m before printing. If output stays low with the gap and speed corrected, the electrode or the high-voltage transformer needs inspection.

Arcing

Visible arcing means the discharge is finding a shorter path than the web - usually a contaminated electrode, a gap set too small, or a bare metal roll edge. Stop the generator before inspecting. Clean the electrode, reset the gap to the value on the approved drawing, and check the roll cover for damage. Persistent arcing at a set gap points to insulation failure and needs a technician.

Overheating

Overheating follows long runs at high power with poor extract. Check the cooling airflow, the ozone extraction path and the ambient temperature around the cabinet. Corona produces ozone as a by-product; the station needs local extraction and the generator a clear ventilation path. A thermal cut-out that trips repeatedly is a symptom to investigate, not a switch to reset.

Frequently Asked Questions

Why does my dyne reading drop when nothing changed?

Usually the reading was taken at the wrong moment - during ramp-up, on a stored roll, or over slip additive that has migrated to the surface. Test in-line on a clean area and confirm with a print trial.

Which corona generator types does HeFeng offer?

2-in-1 cabinet, floor-standing and hanging styles. The troubleshooting steps above are common to all three; sizing depends on web width and line speed.

When should I call a technician instead of troubleshooting myself?

Stop and call when you see arcing that persists after cleaning and gap reset, a burnt smell, or a thermal cut-out that trips repeatedly. These point to high-voltage insulation or transformer faults.